SIP SOLUTIONS TRUNKING
Configuration Settings, Notes, & Recommendations
Page 10
March 2012
All payload type entries must be configured to a value of ‘101’ as shown below. Since Comfort
Noise is not supported, the Enable RFC 3389 CN Payload Type must be set to ‘Disable.’ In
addition, the Comfort Noise Generation Negotiation field must be set to ‘Disable.’
Finally, the RTP Base UDP Port value must be set. In the testing and certification process, port
6000 was used, as shown below. However, this value is variable based on the customer internal
network configuration requirements. Unless, there is a specific need to use a different port
value, 6000 worked well for RTP traffic.