Installation Manual 58 Document #: LTRT-83506
Mediant 1000
Table 4-3: BRI I/O Modules LED Description
LED Color State Description
RJ-45 Green On Physical layer (Layer 1) is synchronized (normal operation).
Red On Physical layer (Layer 1) is not synchronized.
- Off
Trunk is not active.
Table 4-4: Power Supply Module LED Description
LED Color State Description
POWER Green On The LED of each AC power supply is lit green when the power
supply is operating correctly.
- Off Failure / disruption in the AC supply, or the power is currently
not being supplied to the device through the AC power supply
entry.
Table 4-5: CPU Module LEDs Description
LED Item # Color State Description
Ethernet
Ports I &
II
2 (Left
LED)
Orange Blinking Activity.
2 (Right
LED)
Green On Link OK.
Yellow Blinking Data is being received.
- Off No link.
General
Purpose
3
Green N/A. (Future support.)