Table 6-7: SIP Configuration Parameters (continues on pages 150 to 169)
ini File Field Name
Web Parameter Name
Valid Range and Description
SITDetectorEnable
Enables or disables Special Information Tone (SIT) detection according to the
ITU-T recommendation E.180/Q.35.
Valid options include:
0 = Disable (default).
1 = Enable.
AMDTimeout
Timeout (in msec) between receiving CONNECT messages from the ISDN and
sending of Answering Machine Detection (AMD) results.
The valid range is 1 to 30,000. The default is 2,000 (2 seconds).
RTPOnlyMode
Enables the gateway to start sending and/or receiving RTP packets to and
from remote endpoints without the need to establish a Control session. The
remote IP address is determined according to the Tel2IP Routing table. The
port is the same port as the local RTP port (set by BaseUDPPort and the
channel on which the call was received).
Valid options include:
0 = Disable (default).
1 = Transmit & Receive.
2 = Transmit Only.
3 = Receive Only.