AudioCodes Mediant Series Spécifications Page 46

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 136
  • Table des matières
  • DEPANNAGE
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 45
Spectralink 84-Series with AudioCodes Gateway and Avaya Communication Manager: Interoperability Guide
1725-86914-000_C.docx
September 2013 46
Configure additional syslog trace settings
Additional trace settings should be set on the Admin Page.
PSTNreserved3: Configures the low level PSTN i.e. Q931 trace messages to be sent to syslog.
1 Enter AdminPage after the IP address in the browser as shown in the screen below.
2 Select ini Parameters in the Nav pane on the left.
3 Enter PSTNReserved3 and the value 8
4 Click Apply New Value.
Facility Trace: Setting this parameter allows you to display the description of the facility
messages in the syslog.
1 Type FacilityTrace in the Parameter Name field and 1 in the Enter Value field.
2 Click the Apply New Value button.
Vue de la page 45